| 5 B 10.811 |
No spectrum currently available |
| No photo currently available |
![]() |
![]() |
References ordered by physical form of material analysed |
GO TO: |
![]() |
![]() |
PHYSICAL FORM OF MATERIAL |
LOD / RSD |
MATRIX |
COMMENTS |
REFERENCE |
|
Solid |
1.5 ppm, 0.3 ppm / RSD not reported (error 5 – 10%) |
Wood |
Single-shot and 20-shot measurements. Nd:YAG laser (1064 nm), Echelle spectrometer & ICCD camera. Al, As, B, Cd, Cr, Cu, Hg, K, Mg, Na, Pb, Si, Sn. |
A. Uhl, K. Loebe and L. Kreuchwig Fast analysis of wood preservers using laser Induced breakdown Spectroscopy. Spectrochim. Acta Part B, 56, (2001), 795-806. |
249.773 / C (247.857) |
Solid |
65 ppm / 10% |
UO2 |
Nuclear fuel pellets. Nd:YAG laser (532 nm). Ag, Al, B, Ba, Bi, Cr, Cu, Fe, Ga, In, Li, Mg, Mn, Pb, Sr, Tl. (Ca, Cd, Co, Na, Zn – LOD not determined) |
P. Fichet, P. Mauchien and C. Moulin. Determination of impurities in uranium and plutonium dioxides by laser-induced breakdown spectroscopy. Appl. Spectrosc., 53, (1999), 1111-1117. |
249.7733 / not applicable |
Solid |
30 ppm, 40 ppm / RSD not reported |
Glass |
Air atmosphere at 1 and 5 Torr. TEA-CO2 laser (10.6 µm) & XeCl excimer laser (308 nm). Li, B, Na, Mg, Al, K, Ca, Ti, Zn, Zr, Ba. |
H. Kurniawan, S. Nakajima, J.E. Batubara, M. Marpaung, M. Okamoto and K. Kagawa. Laser-induced wave plasma in glass and its application to elemental analysis. Appl. Spectrosc., 49, (1995), 1067-1072. |
|
Liquid |
0.054 ppm (estimated) / RSD not reported |
Electro- deposited metals on nickel electrode |
TEA CO2 laser, vacuum sample chamber, monochromator and PMT detector. Metals electro-deposited on nickel plate electrode from aqueous solutions. B, Cu, Fe, Li, Pb. |
M. Pardede, H. Kurniawan, M.O. Tjja, K. Ikezawa, T. Maruyama and K. Kagawa. Spectrochemical analysis of metal elements electrodeposited from water samples by laser-induced shock wave plasma spectroscopy. Appl. Spectrosc., 55, (2001), 1229-1236. |
249.7 / not applicable |
Liquid |
80 ppm / 4 – 8% |
Water, Organic solvents |
RSP (double pulse). Plasma formed within the liquid. Nd:YAG laser (1064 nm). Li, Na, K, Rb, Cs, Be, Mg, Ca, B, Al. PMT detector. |
D.A. Cremers, L.J. Radziemski and T.R. Loree. Spectrochemical analysis of liquids using the laser spark. Appl. Spectrosc,. 38, (1984), 721-729. |
249.68 & 249.77 / not applicable |
Liquid |
1200 ppm / 4 – 8% |
Water, Organic solvents |
RSS (single pulse). Plasma formed within the liquid. Nd:YAG laser (1064 nm). Li, Na, K, Rb, Cs, Be, Mg, Ca, B, Al. PMT detector. |
D.A. Cremers, L.J. Radziemski and T.R. Loree. Spectrochemical analysis of liquids using the laser spark. Appl. Spectrosc,. 38, (1984), 721-729. |
249.68 & 249.77 / not applicable |